SPRVSR+ Plug-In and Wisenet Wave Integration
With the development of technology, systems such as elevators, security cameras, card passes, fire detection and alarm systems with different mechanical and electronic features; It is used together in increasingly complex structures. Framework software is developed for this situation, which creates the need for management from a single center, and these software become much more preferred as a result of the technological partnerships of expert system manufacturers.
Being the solution partner of Mavili and Hanwha Techwin, which was founded in 1990 and has a great importance in the field of video management systems, has made a significant difference in ensuring the safety of life and property against fires that may occur in the areas where smart building technology is used.
Mavili’s Maxlogic SPRVSR + Plug-In software has been integrated into the framework software named Wisenet Wave, owned by Hanwha Techwin. Thus, detailed map and device information of the location to be monitored and controlled can be accessed through this software.
◗ Graphical display of Maxlogic & Mavigard brand fire detection and alarm devices on the floor plan
◗ Access to detailed map and device information of the location
◗ Ability to realize all interventions that can be made with the power plant
◗ Switching between maps automatically as well as manually
◗ Firstly, information about the fire can be displayed on the screen in the form of a pop-up in fire status.
◗ Displaying the location from which fire information is received from the cameras that match the device with which the fire alarm is received.
In case of fire; Information about the fire is displayed in the form of a pop-up message at the upper right corner of the screen. The matched camera or cameras are automatically turned on with another tab when the fire alarm signal comes from matched device.
Logs of all events occuring in the system are displayed on the «Events» section in the right side of the screen or these event logs, filtering can be made according to different criteria such as date, time, event status and severity.
After the fire information is received, the system is intervened in two different ways.
1) Via the Alarm, Silence Alarm, Silence Buzzer, and Reset buttons in the Devices menu,
2) Other one is remote control operation by accessing the interface of the panel on the map.
SOFTWARE MODELS |
|
Product Code | Description |
ML-1634.1 |
Maxlogic SPRVSR+ Graphical Monitoring and Control Android Software using cost, 1 user |
ML-1634.5 | Maxlogic SPRVSR+ Graphical Monitoring and Control Android Software using cost, 5 user |
ML-1634.10 | Maxlogic SPRVSR+ Graphical Monitoring and Control Android Software using cost, 10 user |
ML-1635.1 |
Maxlogic SPRVSR+ Graphical Monitoring and Control IOS Software using cost, 1 user |
ML-1635.5 | Maxlogic SPRVSR+ Graphical Monitoring and Control IOS Software using cost, 5 user |
ML-1635.10 |
Maxlogic SPRVSR+ Graphical Monitoring and Control IOS Software using cost, 10 user |
ML-1636.7 |
Maxlogic SPRVSR+ Plug-In Graphical Monitoring Software Using cost, Wisenet Wave Integration |
DONGLE MODELS |
|
Product Code | Description |
ML-1661.1 |
Maxlogic SPRVSR+ Master USB Dongle |
ML-1661.2 |
Maxlogic SPRVSR+ Slave USB Dongle |
ML-1661.3.7 |
Maxlogic SPRVSR+ Plug-In USB Dongle using cost, Wisenet Wave Authorization |