8 Channel Input/Output Modules

Description

Programmable to work in cause-and-effect scenarios for fire automation, Supervised Input/Output (I/O), Relay Control, Contact Monitoring, Sounder Control, and Zone Control modules offer superior performance with the VIP communication protocol.

Maxlogic Intelligent Addressable System Modules offer tailored choices to meet your needs, including 8-output Relay Control, 8-input Contact Monitoring, 8-output Sounder Control, and 8-input Zone Control Modules.

There are also options available to meet specific zone requirements, including 4 channel Contact Monitoring and 4 channel Relay Control Modules for zone needs, as well as 4 channel Zone Monitoring and 4 Channel Sounder Control Modules.

Besides communication and fault statuses, the status of input/output lines can be easily monitored through the LEDs on the modules.

◗ Compatible with EN 54-17 ve EN 54-18 standards

◗ Short circuit isolator option

◗ Working status control through LED’s

◗ Easy mounting with Rail system

Dry Contact Input/Output Modules

The modules take their energy from the loop and can be programmed to work in cause-and-effect scenarios. Within the scope of fire automation, contact monitoring inputs can be used to monitor desired peripheral systems, and relay outputs can be used to control the desired peripheral systems. The contact monitoring inputs are used to monitor external dry contact (voltage-free) relay outputs. They have both normally open and normally closed operation features. In case of a change in the contact status, the type of event that the control panel will detect can be determined by the user. The double-pole dry contact (voltage-free) relay output, capable of withstanding a maximum of 30V DC and 1A current, has normally open and normally closed contact positions. It can be configured to provide output based on the event type defined by the user. Models with SCI feature isolate the line in case of potential short-circuit situations, thanks to the built-in short-circuit isolator.

Powered Input/Output Modules

It requires an external power source of 18V – 30V DC and this source can be monitored for fault conditions. It can be programmed to work in cause-and-effect scenarios. Contact monitoring inputs are used to monitor external dry contact (voltage-free) relay outputs. They have both normally open and normally closed operation features. In case of a change in the contact status, the type of event that the control panel will detect can be determined by the user. The 24V DC 500mA sounder output can be activated as desired within the scope of fire automation. It can be configured to provide output based on the event type defined by the user. Models with SCI feature isolate the line in case of potential short-circuit situations, thanks to the built-in short-circuit isolator.

LOOP POWERED MODULE MODELS
Product Code Description
ML-1318 Maxlogic Intelligent Addressable System Relay Control Module, 8 Output
ML-1318.SCI Maxlogic Intelligent Addressable System Relay Control Module, 8 Output, Short Circuit Isolator
ML-1328 Maxlogic Intelligent Addressable System Switch Monitor Module, 8 Input
ML-1328.SCI Maxlogic Intelligent Addressable System Switch Monitor Module, 8 Input, Short Circuit Isolator
ML-1351 Maxlogic Intelligent Addressable System 4 Switch Monitor, 4 Relay Control Module
ML-1351.SCI Maxlogic Intelligent Addressable System 4 Switch Monitor, 4 Relay Control Module, Short Circuit Isolator
EXTERNALLY SUPPLY MODULE MODELS
Product Code Description
ML-1338 Maxlogic Intelligent Addressable System Sounder Control Module, 8 Output
ML-1338.SCI Maxlogic Intelligent Addressable System Sounder Control Module, 8 Output, Short Circuit Isolator
ML-1348 Maxlogic Intelligent Addressable System Zone Control Module, 8 Input
ML-1348.SCI Maxlogic Intelligent Addressable System Zone Control Module, 8 Input, Short Circuit Isolator
ML-1352 Maxlogic Intelligent Addressable System 4 ZoneMonitor, 4 Sounder Control Module
ML-1352.SCI Maxlogic Intelligent Addressable System 4 ZoneMonitor, 4 Sounder Control Module, Short Circuit Isolator
ML-1380 Maxlogic Intelligent Addressable System Short Circuit Isolator
ML-1390 Maxlogic Intelligent Addressable System Short Circuit Isolator
ML-0320 Maxlogic 2-I/O Module Protection Box

You can find the connection diagram (DWG) of the product here.

You can find the connection diagram (PDF) of the product here.

You can find the connection diagram (REVİT) of the product here.